Structural Steel Beams

IPE 360 vs HEA 200

Empirical head-to-head comparison table, delta analysis, and interactive formula calculators.

IPE 360

Standard Eurocode
Depth mm 360
Flange Width mm 170
Web Thick mm 8
Flange Thick mm 12.7
Area cm2 72.7
Weight kg m 57.1
Moment Inertia Ix cm4 16270
Section Modulus Sx cm3 903.6
VS

HEA 200

Standard Eurocode
Depth mm 190
Flange Width mm 200
Web Thick mm 6.5
Flange Thick mm 10
Area cm2 53.8
Weight kg m 42.3
Moment Inertia Ix cm4 3692
Section Modulus Sx cm3 388.6

📊 Delta & Performance Analysis

Direct comparative ratio of core numeric metrics between IPE 360 (Cyan) and HEA 200 (Gold).

Depth mm: 360 vs 190 Δ +170
Flange Width mm: 170 vs 200 Δ -30
Web Thick mm: 8 vs 6.5 Δ +1.5
Flange Thick mm: 12.7 vs 10 Δ +2.7
Area cm2: 72.7 vs 53.8 Δ +18.9
Weight kg m: 57.1 vs 42.3 Δ +14.8
Moment Inertia Ix cm4: 16270 vs 3692 Δ +12578
Section Modulus Sx cm3: 903.6 vs 388.6 Δ +515

Solve Live Formulas with Interactive Tools

Run real-time calculations using our laboratory instruments, programmatic REST API, or raw CSV/JSON datasets.

⚡ Launch Beam Deflection Calculator 📥 Download Structural Steel Beams Explore All Comparisons

Frequently Asked Questions

What are the primary differences between IPE 360 and HEA 200?

IPE 360 and HEA 200 represent distinct specifications within Structural Steel Beams. Reference the side-by-side data table above for exact empirical values.

Can I access this comparison data programmatically via API?

Yes. GemsMakers offers a high-speed, zero-authentication JSON REST API at https://gemsmakers.com/api/v1/calculate.php and downloadable datasets in both CSV and JSON formats under CC BY 4.0.